Kansas City Area (Clay, Jackson and Platte counties)

Vaport recovery equipment

Unless otherwise exempt, under the most recent amendment to 10 CSR 10-2.260, owners/operators with tanks between 550 gallons and 40,000 gallons in the Kansas City area, are required to use pressure/vacuum valves that are California Air Resources Board certified or department approved. The pressure/vacuum valve must have a positive pressure setting of 2.5 to 6.0 inches of water column and a negative pressure setting of 6.0 to 10.0 inches of water. Following is a list of the pressure/vacuum valves that are approved for use in the area:

Pressure/Vacuum Vents + 

  • FFS P/V Zero
  • Husky 4885 
  • Husky 5885
  • OPW 623V 
  • OPW 723V 
  • Morrison Brothers model 948A

St. Louis Area (Franklin, Jefferson, St. Charles and St. Louis counties and the City of St. Louis)

Unless otherwise exempt, under the most recent amendment to 10 CSR 10-5.220, owners/operators in the St. Louis area have gasoline storage tanks with a capacity greater than 1,000 gallons and less than 40,000 gallons are required to install a Stage I vapor recovery system that demonstrates 98 percent collection efficiency. 

The gasoline storage tank must be equipped with enhanced vapor recovery components that are approved by a California Air Resources Board’s executive order or that are approved by the department’s Air Pollution Control Program as having a collection efficiency of 98 percent. View the most recent California Air Resources Board’s executive orders. The gasoline storage tank must include the following enhanced vapor recovery components: 

  • A rotatable product adaptor.
  • A product adaptor dust cap.
  • A rotatable vapor recovery adaptor.
  • A vapor recovery dust cap.
  • A product spill container.
  • A drop-fill tube or drop-fill tube with overflow prevention.
  • Any other component that is newly installed but not listed above must be enhanced vapor recovery approved if an enhanced vapor recovery equivalent is available.

The following list includes components that are approved for use in the St. Louis area:

Ball Float + 
  • OPW 61VSA-MA (GAS/E85)
  • Universal Model 37
Bladder Plug + 

◦ McGard PSI104

Drain Valve Kit + 
  • CNI Mfg. RP12-Push
  • EBW 705-337-19
  • EBW 70533729 (Gas)
  • EBW 708-255-01 DrainValve Isolation Kit
  • EBW 90022 Drain Valve Blank 
  • EBW 90079 Isolation test kit
  • EBW 90089 Drain Valve Security Blank Kit
  • EMCO Model 494118
  • OPW 1DK-2100 (GAS/E85)
  • OPW 1DP-2100 Drain Plug Kit
  • Phil-Tite 85400 (Gas/E85)
Drop Tube (components) + 
  • CNI Mfg. DT100 (various lengths)
  • CNI Mfg. DT101 Drop Tube O Ring (original)
  • CNI Mfg. RP101 Drop Tube O Ring (replacement)
  • EBW 782-2041X-2
  • EBW 782-204-3X2 (Gas/E85) 
  • EMCO Model A0020EVRC-X
  • EMCO Model A0020EVR-X
  • EMCO Wheaton Retail Drop Tube O Ring 569461
  • FFS 70550901EC (Drop tube Riser clamp)
  • OPW 61T (various lengths)
  • OPW 61T-SS (various lengths) (GAS/E85)
Drop Tube with Device to Prevent Overfill + 
  • EBW Defender Series OPV 70859X9YZ 
  • EBW 708 49X 1Y (Gas)
  • EBW 708-49X-3Y (Gas/E85)
  • EBW 90079 Drop Tube Isolation Test Kit
  • EMCO Model A1100EVR-X
  • OPW 61SO
  • OPW 61SOM-412C-EVR (GAS/E85)
  • OPW 71SO
  • OPW 71SO Testable
  • OPW 71SOM-412C (GAS/E85)
Extractor Valve + 
  • OPW 233-series (-4432 tested)
  • Universal Model V421
Face Seal Adaptor + 
  • OPW FSA-400
  • OPW FSA-400-S (Gas/E85)
Fuel Lock + 
  • McGard FL1 – Standard Fuel Lock (125007)
  • McGard FL1 – Standard Fuel Lock (125007)
  • McGard FL2 – Sampling Fuel Lock 25008
  • McGard FL2 – Standard Fuel Lock (125008)
Jack Screw Kit + 
  • OPW 61JSK-4410 
  • OPW 61JSK-44CB 
  • OPW 61JSK-4RMT (Only Used on Remote Fill)
  • OPW 71JSK-44MA (GAS/E85)
  • OPW 71JSK-4RMT (GAS/E85)
Pressure Vacuum Vent + 
  • FFS P/V Zero
  • Husky 4885 
  • Husky 5885
  • OPW 623V 
  • OPW 723V 
  • Morrison Brothers model 948A
Product Adaptor + 
  • EMCO A0030-124S
  • OPW 61SALP-1020-EVR
  • OPW 61SALP-MA (Gas/E85)
  • Phil-Tite SWF-100-B (Gas)
  • Phil-Tite SWF-100-SS (Gas/E85)
Riser Components + 
  • EMCO Model 494096
  • Phil-Tite M/F 4X4* (Gas/E85)
  • Phil-Tite M/F 4X4-R* (Gas/E85)
  • Phil Tite M 1600 (Riser Support Bracket)
  • Phil-Tite M-6050 Riser Offset
Spill Container + 
  • CNI 205P - Product Assembly - 5 gal
  • CNI 205V - Vapor Assembly
  • CNI 214P - Product Assembly - 5 gal
  • CNI 214V - Vapor Assembly - 5 gal
  • CNI CON1-31103
  • CNI CON2-31103
  • CNI Mfg. GAC Gravity Cover
  • CNI Mfg. STP-200 Snap Tight Cover
  • CNI Mfg. STP-39 Snap Tight Cover Ring
  • EBW 7054401X (lid)
  • EBW 7XX-49Y-0Z
  • EBW 90087 Upgrade Kit (product)
  • EBW 90088 Upgrade kit (vapor)
  • EBW Defender 705 Series*
  • EMCO Model A1004EVR-X Series
  • OPW 1-2100 Series
  • OPW 1-2200 Series
  • OPW 1-3100 Series
  • OPW P500 Series
  • OPW P700 Series
  • Phil-Tite 85000 Series (Gas/E85)
  • Phil-Tite 85011* Spill Container Lid (Gas/E85)
Tank Bottom Protector +  
  • PHIL-TITE TBP-3516-E (Gas/E85)
 Tank Gauge (in tank probe cap and adaptor) + 
  • CNI Mfg. 613BC set (Cap 64, Adaptor 613)
  • EBW 90037 (In Tank Probe Cap and Adaptor Kit) (Gas)
  • EBW 90037-E (In Tank Probe Cap and Adapter Kit) (Gas/E85)
  • EMCO Model A0030-014 (Adaptor)
  • EMCO Model A0097-010 (Cap)
  • Morrison Brothers 305-0200AAEVR (replacement adaptor) (Gas/E85)
  • Morrison Brothers 305XP-110ACEVR (replacement cap) (Gas/E85)
  • Morrison Brothers 305XPA1100AKEVR (cap and adaptor kit) (Gas/E85)
  • OPW 62M (Cap and Adaptor)
  • OPW 62M-MA (GAS/E85)
  • Veeder-Root 312020-952 (cap and adaptor kit) (Gas/E85)
Vapor Adaptor + 
  • EMCO Model A0076-124S
  • Emco Wheaton Retail A0076-124
  • OPW 61VSA
  • OPW 61VSA-MA (GAS/E85)
  • Phil-Tite SWV-101-B (Gas)
  • Phil-Tite SWV-101-SS (Gas/E85)
Vapor/Product Dust Cap + 
  • CNI Mfg. 611-VR-3 (vapor)
  • CNI Mfg. 64 (product)
  • CNI Mfg. 65 Dust Cap Gasket
  • CNI Mfg. RP65 (Dust cap gasket replacement)
  • CompX CSP1-634LPC
  • CompX CSP2-634LPC (product)
  • CompX CSP3-1711LPC (vapor)
  • CompX CSP4-1711LPC (vapor)
  • EBW 304 301 XX (vapor) (Gas)
  • EBW 304-200-XX (vapor) (Gas)
  • EBW 777-201-02 (product) (Gas)
  • EBW 777-202-02 (product) (Gas/E85)
  • EMCO MODEL A0097-005 (product)
  • EMCO Model A0099-X (vapor)
  • Morrison Brothers 305C-0100ACEVR (product) (Gas/E85)
  • Morrison Brothers 323C-0100ACEVR (vapor) (Gas/E85)
  • OPW 1711LPC (vapor) (GAS/E85)
  • OPW 1711T-EVR (vapor) (GAS/E85)
  • OPW 634LPC (product) (GAS/E85)
  • OPW 634TT-EVR (product) (GAS/E85)

 

Contact Information

Kansas City Regional Office

Address

Division of Environmental Quality
200 Unity Circle North, Suite 2A
Lee's Summit, MO 64086-6018
United States

Toll-free